To configure a different port for Runtime Server, complete the following steps.

  1. In Windows registry, complete one of the following substeps.
    • For a 32-bit machine, navigate to HKEY_LOCAL_MACHINE\SOFTWARE\Hyland_BW\Services.

    • For a 64-bit machine, navigate to HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Hyland_BW\Services.
  2. In the right pane, right-click and then click New > DWORD (32-bit) Value.
  3. In the Name field, type Port.
  4. Right-click the Port key and then click Modify.
  5. In the Edit DWORD (32-bit) Value dialog box, in the Value data field, type the number of an available port and then click OK.
  6. Restart Brainware Intelligent Capture Runtime Server service.
  7. Repeat the previous steps on all BIC servers.