Convert Existing Project Files to the Current Version - Brainware Intelligent Capture - Foundation 23.1 - Foundation 23.1 - Brainware - external

Brainware Intelligent Capture Update

Platform
Brainware
Product
Brainware Intelligent Capture
Release
Foundation 23.1
License

You must convert project files created in an earlier version before you can use them.

To convert existing project files, complete the following steps.

  1. In Designer, click File > Load Project.
  2. In the Brainware Intelligent Capture – Load Project dialog box, select a project and click Open.
  3. In the Brainware Intelligent Capture – Project Logon dialog box, log on with Administrator credentials and then click OK.
    Note: The fully automated conversion process may take a few minutes, depending on the project size.
  4. If prompted, confirm the error message about the missing FineReader 8.1 engine.
  5. Verify if you need to modify the scripts.
  6. To verify the settings, click Options | Settings.
  7. In the Settings dialog box, complete the following substeps.
    1. On the Input Mode tab, verify that the required job name is selected or that the Batch Root Directory points to the required batch directory.
    2. On the Train Mode tab, verify that the Learn Set Manager base directory points to the required directory and then click OK.
  8. Switch to Train Mode.
  9. On the Options menu, clear Incremental Learning.
  10. To rebuild the learn set under the current version, on the Toolbar, click Learn documents
  11. Switch to Definition Mode.
  12. the left pane, on the Classes tab, right-click the project and then click Show Properties.
  13. In the right pane, on the Project tab, click OCR settings.
  14. In the OCR Properties dialog box, complete the following substeps.
    1. On the Recognition tab, under Available Engines, verify that FineReader 11 is selected.
    2. Verify the settings on the different tabs.
  15. BIC now provides the possibility to perform a combined OCR for Korean and English in one selection. If your project uses Korean and English, in the OCR Properties dialog box, complete the following substeps.
    1. On the Languages tab, under Used, remove English and Korean.
    2. Under Installed, select Korean+English, click and then click OK.
  16. Upgraded projects may have correlation enabled for table fields. To review and disable this setting if not applicable for this project, complete the following substep.
    • In Definition Mode, open the properties of all table fields and clear the correlation option on the Advanced tab of the Analysis pane.
  17. For local projects, complete the following substeps.
    1. Click Options | Users, Groups and Roles.
    2. On the Users tab, select Allow Database Authentication and then click OK.
  18. Click File | Save Project.
  19. Repeat the previous steps for each project.