The OCR, classification and extraction workflow steps are highly
CPU-intensive. You can clone instances that execute these steps to enhance
performance. The cloned instances inherit the settings of the original
instance. To clone an instance, complete the following steps.
-
In
Windows registry, complete one of the
following substeps.
- On a 32-bit system, navigate to
HKEY_LOCAL_MACHINE\Software\Hyland_BW\Services\[Instance
name].
- On a 64-bit system, navigate to
HKEY_LOCAL_MACHINE\Software\Wow6432Node\Hyland_BW\Services\[Instance
name].
-
Click New | DWORD (32-bit) Value.
-
In the
Name field, type
InstanceCount.
-
Right-click
InstanceCount and click
Modify.
-
In the
Edit DWORD (32-bit) Value dialog box, in the
Value data field, type the number of
instances.
-
Restart the
Brainware Intelligent Capture Runtime Server
service.
Note: Do not clone instances that execute the import and
cleanup steps. This does not enhance performance.