To modify the security options:
  1. To open the Local Security Policy, in the Windows search box, enter secpol.msc.
  2. In the Local Security Policy window, navigate to Local Policies > Security Options.
  3. Locate the Interactive logon: Do not require CTRL + ALT + DEL policy and set its security setting to Enabled.
  4. Locate the Interactive logon: Message text for users attempting to log on policy and ensure that its security setting does not contain a value.