To enable the TAB Cycles Through Suspect Keywords option for a scan queue using a custom capture process:

  1. From OnBase Studio, select the Capture Process tab in the Repositories pane.
  2. Within the Capture Process tab, open the scan queue and capture process to be used for Advanced Capture processing.
  3. In the design view pane, select the Index status step configured for performing Advanced Capture index verification. The indexing process options are displayed in the General tab of the Properties pane.
  4. Select the TAB Cycles Through Suspect Keywords check box in the Indexing Focus section of the indexing process options.
  5. Click Save on the Home ribbon.