The Status Window Update Interval parameter controls the frequency of updates to the status bar while a process is running. When the interval is set to 1, the status bar will be updated each time a new document is created. If the update interval is set to 10, the status bar will be updated after 10 new documents have been created.
This parameter should be set so that updates occur no more than once per second. Ideally, this should be set so that updates occur about every 5 seconds. For example, if the process is creating 10 documents per second, the Status Window Update Interval should be set to 5 or greater. Updating the status bar is a time consuming process, so increasing the update interval can significantly increase the speed of a process. The range of values is 10–3000.