Patient context syncing can be enabled for custom integrations with Allscripts ™, where DeficiencyPop is embedded within Allscripts ™ Sunrise Acute Care. You may need to work with your solution provider to determine whether context syncing can be enabled in your environment.

Note:

Patient context syncing supports Internet Explorer and WebView2-based browsers, such as Microsoft Edge.

Where supported, patient context syncing allows Sunrise Acute Care to remain synchronized with DeficiencyPop. When the physician selects a deficiency in DeficiencyPop, DeficiencyPop sends the associated MPI, MRN, and chart ID (with assigning authorities, if applicable) to Sunrise Acute Care, allowing Sunrise Acute Care to retrieve the relevant patient visit.

To enable patient context syncing:

  1. In OnBase Configuration, select Medical | User Interface Settings | DeficiencyPop | Settings. The Deficiency Pop Settings dialog box is displayed.
  2. Select Enable Patient Context Syncing.
  3. Click Save.