Troubleshooting - Troubleshooting - OnBase - EIS Message Broker - OnBase/EIS-Message-Broker/Foundation-24.1/EIS-Message-Broker/Installation/Troubleshooting - Foundation 24.1 - Foundation 24.1

EIS Message Broker

Platform
OnBase
Product
EIS Message Broker
Release
Foundation 24.1
License
Premier
Standard
ft:lastPublication
2025-04-01T14:28:20.321000
ft:locale
en-US

Issue:

When attempting to publish a message, an error similar to the following is displayed:

  • Keyword Type 101 not found on Document Type 123

  • Missing field with ID 234

  • Missing repeater with ID 345

  • Missing nested table with ID 456

Resolution:

This type of error occurs when a OnBase object used in a message type is reconfigured so that a Keyword Type, WorkView attribute, or E-Form/Unity Form field is removed from the OnBase object. For example, the first error is displayed if a Keyword Type is removed from a Document Type used by the selected message type. If you must remove a Keyword Type, WorkView attribute, or E-Form/Unity Form field from an OnBase object that is used by a message type (such as a Document Type or E-Form), you must also remove that value from the associated message type(s).