When you create an on-ramp for two-way communication, a system event is automatically created to handle communication from that on-ramp. This ensures that the system event has a direct relationship with the on-ramp, and typically the system event itself requires no further configuration. However, if needed, you can add or remove on-ramps on a system event.
When configuring a system event for Workflow Messaging, note the following considerations:
-
Each system event must be configured with at least one on-ramp.
-
You cannot add an on-ramp to more than one system event.
-
You can add more than one on-ramp to a system event. This is not a typical use case.
To configure a Workflow Messaging system event:
- Expand the list of available system events by clicking the arrow next to the System Events node in the Workflow tab of the Repositories pane.
- Select the system event you want to edit. Settings for the system event are displayed in the Properties pane.
- Click the On-Ramp tab in the Properties pane. This tab lists the on-ramps associated with the system event.
-
To add an on-ramp:
- Click Add. The On-Ramp dialog box is displayed. This dialog box lists the available on-ramps
- Select the check box next to the on-ramp you want to add to the system event, and click OK.
- To remove an on-ramp, select the on-ramp and click Remove.