Configure the Adapter Properties - Enterprise Integration Server - Foundation 23.1 - Foundation 23.1 - Ready - OnBase - Premier - Standard - external - Standard - Premier

Enterprise Integration Server

Platform
OnBase
Product
Enterprise Integration Server
Release
Foundation 23.1
License
Standard
Premier
  1. Follow the steps outlined under Consuming the Hyland Adapter to consume the Hyland Adapter.
  2. On the URI Properties tab of the Configure Adapter dialog box, specify these additional options:

    Option

    Description

    UseServiceBusEndpoint

    Set this option to True to configure your system to connect with Windows Azure. If this option is set to False, EIS will not attempt to connect to Windows Azure.

    ServicebusScheme

    Set this option to the Azure service bus scheme.

    ServiceNamespace

    Set this option to the name of the Azure service bus.

    ServicePath

    Set this option to the name of the Azure service bus endpoint.

  3. On the Binding Properties tab of the Configure Adapter dialog box, specify these additional options:

    Option

    Description

    IssuerName

    Set this option to the user name of the owner of the Azure service bus.

    IssuerSecret

    Set this option to the secret key for the owner of the Azure service bus.

    EnableConnectionPooling

    Leave this option at the default value of True.

  4. Close out of the Consume Adapter Service dialog box.