Configure the Application Event Log - Enterprise Integration Server - Foundation 23.1 - Foundation 23.1 - Ready - OnBase - Premier - Standard - external - Standard - Premier

Enterprise Integration Server

Platform
OnBase
Product
Enterprise Integration Server
Release
Foundation 23.1
License
Standard
Premier

BizTalk Server setup keeps a record of events in the Application Event Log. Depending on the BizTalk Server features installed, the amount of space required in the log may exceed its limit. If the application event log runs out of space during BizTalk Server setup, the installation will fail.

To prevent this from happening, you can change the settings in the Application Event Log.

To change settings in the Application Event Log:

  1. Click Start, click Control Panel, and then double-click Administrative Tools.
  2. Click Event Viewer.
  3. In the Event Viewer, expand Windows Logs.
  4. Right-click Application, and then click Properties. This opens the Log Properties dialog box.
    • To see how much available space your log has, compare the Log Size field with the Maximum log size field.

    • To provide more space in the event log, enter a higher number in the Maximum log size field.

    • To enable overwriting of old events when the log becomes full, select Overwrite events as needed.

    • To clear the log events, click Clear log.

  5. Click OK, close the Event Viewer, and close Administrative Tools.