Repeating segments allow multiple sets of information to be sent within a single HL7 message. If you need to map different Keyword Types or values to a field in a repeating segment, you must configure the message template to use Set ID filtering.

The Set ID is a number that populates the first field in a repeating segment. Each time the segment repeats, the Set ID increments by one. For information about Set IDs and the segments that use them, see the HL7 standard specification.

To configure a message template for Set ID filtering, you must create copies of the repeating segment and add them to the template. Each copy of the segment must be assigned its own Set ID and field settings. This configuration allows the HL7 Listener to process fields in repeated segments differently depending on the Set ID of the segment.