AutoFills that include the MRN, Master Patient Index, or Chart ID Keyword Type should also include an assigning authority Keyword Type. When the identifier is a secondary Keyword Type, the HL7 Back-end Job Processor will use the assigning authority to identify the correct AutoFill instances to update in any of the following events:
-
An MRN merge using the Medical Records Chart or Scripted Message Processor message action
-
An MRN merge using the Merge Into AutoFill Keyword Sets And Documents message action
-
A reverse-keyset update using the AutoFill Keyword Set message action (where the action's target AutoFill uses the MRN, Master Patient Index, or Chart ID Keyword Type as its primary Keyword Type)