Inconsistent Use of Assigning Authority in Message Templates - HL7 Module - English - Foundation 22.1 - OnBase - Premier - external - Standard - Essential - Premier - Standard - Essential

HL7 Module

Platform
OnBase
Product
HL7 Module
Release
Foundation 22.1
License
Premier
Standard
Essential

On systems that allow overlapping MRNs, the following error may be displayed when you click the Validate button on the HL7 Import Process Configuration dialog box in OnBase Configuration:

  • Inconsistent use of Assigning Authority in message templates. The following templates are not configured to use Assigning Authority:

The message then lists all import processes that are not correctly configured for assigning authorities.

Message Action

Description

AutoFill Keyword Set

If the selected AutoFill Keyword contains the MRN Keyword Type, then it must also include the Assigning Authority Keyword Type.

Medical Records Chart

If any message template used for chart processing is configured for MRNs with Assigning Authorities, then every template used for chart processing must be configured for MRNs with Assigning Authorities.

Merge Into AutoFill Keyword Set And Documents

If any AutoFill Keyword Set in the system is configured for MRNs with Assigning Authorities, then all AutoFill Keyword Sets containing the MRN Keyword Type must also contain the Assigning Authority Keyword Type.

Patient Record Processor

If any message template used for patient record processing is configured for MRNs with Assigning Authorities, then every template used for patient record processing must be configured for MRNs with Assigning Authorities.

If you have configured either of the following message actions for assigning authorities, then every template used with these message actions must be configured to support assigning authorities:

  • AutoFill Keyword Set

  • Medical Records Chart

  • Merge Into AutoFill Keyword Set And Documents

  • Patient Record Processor

If you have configured either of the following message actions for assigning authorities, then every template used with these message actions must be configured to support assigning authorities:

  • Medical Records Chart

  • Patient Record Processor

Ensure all templates used by these message actions are configured as described under Configuring HL7 Message Templates for Overlapping Identifiers.