Usage of Assigning Authority Must Be Consistent Between Target and Source - HL7 Module - English - Foundation 22.1 - OnBase - Essential - Premier - Standard - external - Essential - Standard - Premier

HL7 Module

Platform
OnBase
Product
HL7 Module
Release
Foundation 22.1
License
Essential
Standard
Premier

On systems that allow overlapping MRNs, the following error may be displayed when an import process is validated by either OnBase Configuration or the HL7 Listener:

  • Usage of Assigning Authority must be consistent between 'Target Medical Record' and 'Source Medical Record'

This error may be logged if the assigning authority field in the PID segment is mapped inconsistently with the assigning authority field in the MRG segment. For example, perhaps both the MRN and assigning authority fields are mapped in the PID segment, but only the MRN field is mapped in the MRG segment.

To address this error, ensure the assigning authority field is consistently mapped in both the PID and MRG segments.