Document Type Not Configured - HL7 Module - English - Foundation 22.1 - OnBase - Essential - Premier - Standard - external - Essential - Standard - Premier

HL7 Module

Platform
OnBase
Product
HL7 Module
Release
Foundation 22.1
License
Essential
Standard
Premier

When the HL7 Listener starts, the following message may be logged to the HL7 Listener window in the OnBase Client or to the HL7 tab in the Diagnostics Console:

  • Error initializing processor "[process name]" [message type], document type was not configured.

This message may be logged for any import process configured to create a document, except for the Centricity Import process.

This message usually indicates the import process is configured to archive documents to the SYS Unidentified Items Document Type. Within OnBase HL7, this Document Type is used only with the Centricity Import process. Other processes must be configured to archive documents to a different Document Type.

To configure the process, select Medical | HL7 | Import Process in OnBase Configuration. See the Configuration chapter for detailed information about configuring import processes.