Duplicate Segments After a Database Upgrade - HL7 Module - English - Foundation 22.1 - OnBase - Premier - external - Standard - Essential - Premier - Standard - Essential - OnBase/HL7-Module/English/Foundation-22.1/HL7-Module/Troubleshooting/Additional-Troubleshooting-for-HL7-Errors-Issues/Duplicate-Segments-After-a-Database-Upgrade - 2024-09-04

HL7 Module

Platform
OnBase
Product
HL7 Module
Release
Foundation 22.1
License
Premier
Standard
Essential

When a database is upgraded, all default segments that were originally assigned to a system Message Template are reassigned. System Message Templates are those marked with an X in the HL7 Message Template Configuration dialog box.

For example, if all message segments except for an MSH segment were removed from the default ADT^A03 Message Template in an earlier database version, all of the message segments that had been removed are added back to the ADT^A03 Message Template after the upgrade.

To customize a Message Template, copy the Message Template, configure that copy, and assign the copied Message Template to any import or export processes as necessary. Copied Message Templates are not updated during a database upgrade.