When the HL7 Listener receives a merge message, the following warning may be logged to either the OnBase Client's HL7 Listener window or the Diagnostics Console's HL7 tab:

  • Warning: no work to perform for merge job due to unknown source identifiers. MPI: [x], MRN: [x], CHT: [x]

This warning indicates that OnBase has received an HL7 merge message that specifies a non-existing record or chart in the message's MRG segment. This warning is logged only when OnBase is running a merge import process with the Ignore invalid "source" values from unmigrated accounts option selected.

This situation does not present a problem if the source chart (in the MRG segment) is not supposed exist in OnBase, as may be the case with historical charts that have not been imported into OnBase.