When the HL7 Listener runs, the following errors may be logged to the Automatic Document Update Processor:
-
Transcription document(#) revision date collision detected (0)
-
Transcription document(#) revision date collision detected (1)
In addition, the following error messages may be logged to the Diagnostics Console:
-
New HL7 revision is same timestamp as current revision of doc (#)
-
New HL7 revision has older timestamp than current revision of doc (#)
These errors indicate the HL7 Listener processed a transcription message where the incoming document's revision timestamp is the same or older than the current revision of the document in OnBase.
When either of these errors is logged, the incoming document is archived to the Document Type specified under Catch replayed transcription message documents to document type in HL7 Settings. The existing document remains unaltered.
For more information, see Capturing Replayed Transcription Messages.