The following name/value pairs are used to configure a Local object for remote initiation servers:

Name

Value

FriendlyName

Enter a name for the local endpoint.

Port

Enter the TCP port used to connect to the local endpoint. Traffic is forwarded from this endpoint to the remote connection.

KeepAliveTimeout

This setting sends network traffic to the configured endpoint at the configured interval if no other traffic is being sent over that endpoint. For example, if you set this setting to 5, and there is no activity over the port for 5 minutes, Message Engine will send a keep alive packet to the configured endoint every 5 minutes.

Note: It is recommended to set the value to 1 minute less than any configured firewall timeout.