Note:

This setting must be manually added to the INI file.

When used with the ISIS scanning, the Minolta PS7000 continuously scans, requiring the user to close OnBase in order to replenish the scanner. Setting this option to 1 when using a Minolta PS7000 with ISIS scanning instructs the client not to use compression when retrieving data from the scanner and to treat the scanner as a flatbed, requiring the user to click a button to scan additional pages. This resolves the issue with the scanner.