Before configuring the DICOM Processor, answer the following questions:

  1. Do you want the DICOM Processor to create placeholder documents for all of the patient's existing studies?
    • This approach is useful if you want to create placeholder documents based on events like patient registration, which may not be associated with specific studies.

    • If you use this approach, incoming HL7 messages do not have to specify a study UID. Messages only need to provide the patient identifier.

    • To use this approach, see Creating Documents from a Federated Search.

  2. Do you want the DICOM Processor to create placeholder documents immediately upon receiving HL7 messages containing study UIDs?
    • This approach allows the DICOM Processor to immediately create placeholder documents as soon as the HL7 messages are received.

    • This approach assumes the HL7 messages contain the information necessary to identify specific studies in the DICOM repository.

    • To use this approach, see Creating Documents for Specific Studies.

  3. Did you answer yes to both questions?
    If so, then you must configure two separate import processes: one to create documents using a federated search, and one to create documents using the study information in the HL7 message.