When a user clicks the Find More Studies button in the OnBase Patient Window, one of the following errors is displayed:

  • Error during Federated Search.

  • Invalid URI: The hostname could not be parsed.

When either error occurs, the user cannot return to the OnBase Patient Window's main interface.

This first error may occur because the user cannot authenticate with the NilRead server, or because the NilRead server specified in OnBase Configuration is invalid. The second error occurs if the NilRead server is specified using an invalid format.

To resolve these errors, do the following:

  1. In OnBase Configuration, select Medical | DICOM | Viewer Integration Settings.
  2. Select NilRead DICOM Integration.
  3. Click Settings.
  4. Make sure the Shared Secret parameter in OnBase Configuration matches the shared secret configured for the NilRead server.
  5. Make sure the Server parameter specifies a valid NilRead server, without the HTTP or HTTPS.
    For more information, see DICOM Parameter Descriptions.