Once you have created a new external system, you must access the Medical Facility configuration, remove the default Meditech external system, and then add the new external system to the list of selected Report Capture external systems.

To replace the default external system with the new external system:

  1. Open the OnBase Configuration Tool.
  2. Select Medical | Facilities | Facility Configuration. The Medical Facility Configuration dialog box is displayed.
  3. Select your Facility and then click External Systems.
  4. From the External System Mappings dialog box, select the Meditech Magic (2) system from the Selected External Systems box, and then click Remove to remove it from the box.
  5. Select the external system you created from the Available External Systems box, and then click Add to add it to the Selected External Systems box.
  6. Click Save.