To activate Meditech Keyword validation, you must configure a verification button in the Express Scanning master configuration file:

  1. Within the Express Scanning master configuration file, locate the BUTTON sub-element for the button that will be used to perform Keyword validation.
  2. Within the BUTTON sub-element, add the meditech setting. This setting controls whether Express Scanning calls out to an external Web service to validate the dataset Keyword Values against the values stored in the Meditech system. The external Web service is accessed via the Application Server.
    If multiple facilities are configured, within the BUTTON sub-element, add the facilityid attribute. Set the attribute value to the facility ID against which you would like to verify.
  3. Set the meditech setting to true(e.g., <BUTTON meditech="true">).
  4. Configure a KEYWORD sub-element for each Keyword Type to which you have mapped the corresponding Meditech chart data fields.
  5. Save and close the configuration file.