Deficiencies can be applied to encounter-level documents displayed in the Analysis window. Deficiencies cannot be applied to patient-level documents, which are shared across multiple encounters.

Note:

If a document needs to be rotated, rotate it and save the rotation before creating a deficiency. If a document is rotated after a deficiency is created, then the deficiency's orientation on the document changes.

To create a deficiency on the document displayed in the Analysis window:

  1. Select the physician whose signature is missing using either of the following methods.
    • Select the physician from the Physician drop-down list. By default, the attending physician is selected.

    • Search for the physician as described under Searching for a Physician.

  2. Select a Deficiency Type from the drop-down:

    Deficiency Type

    Description

    Signature

    Place this Deficiency Type on documents that require a physician's signature.

    Missing Info

    Place this Deficiency Type on documents that are missing required information. Physicians complete these deficiencies by typing out the required information. Once completed, the Missing Information deficiency is replaced with both the text the physician provided and the physician's signature.

  3. Select Click to Place Deficiency. The button label changes to Placing Deficiencies, indicating the document viewer is in deficiency creation mode.
    Note:

    This button is unavailable if the document is a patient-level document, which is shared with multiple encounters. Deficiencies can be placed only on encounter documents.

  4. Place the deficiency on the document as described in one of the following procedures:
  5. When you are finished creating deficiencies, click the Return to Epic button from the lower-left corner of the Analysis window.
    Note:

    The maximum number of deficiencies that can be placed on a document is 50.