The following errors may be encountered.

Error

Possible Cause

“Please provide an ODBC source on the command line.”

This error is caused because the -ODBC switch was not specified in the command line of the CenteraService executable. DCS requires a database connection. See, Command-Line Switches.

“Error connecting to ODBC data source.”

This error is caused because the database referenced by the -ODBC switch is not available. DCS requires a database connection. See, Command-Line Switches.

“Error loading Centera DLLs.”

This error is caused because the Centera DLLs were not found in the appropriate directory.

“No Centera Servers configured in DB.”

This error is caused when Centera Disk Groups have not been configured. See, Configuration.

“Error starting listener:”

This means that a low-level socket error occurred, which could be caused by another application using the same socket.