The master configuration files contain logon profiles, capture profiles, scanning profiles, and custom settings from the originating computer. To copy these files to all Windows users on the same server, complete the following steps.

You must have a scanner installed on the target Perceptive Content computer and upload enough CaptureNow licenses on the ImageNow Server for your scanners. If you use Kofax software, create the correct source in the Scanning Configuration Utility for VRS 4.1.
  1. Back up the inscan.xml, indevice.xml, and imagenow.ini files and, if needed, the other scanning configuration files.
  2. Copy the XML and INI files to the inclient directory on the target computer and overwrite any existing files with the same names.
    The files you have copied are now the master configuration files.
  3. In each [drive]:\Documents and Settings\<username>\Application Data directory, delete the Perceptive Content folder.
    The <user name> folder is the name for each Windows user account that logged in to Perceptive Content on the target computer.